St. Lic#531108
materialsbutton.gif
 

NewNumber.jpg


 

Material Description and Usage

Provided here is a brief explanation of some of the products we install.

Look through the pages below and find one suitable for your application.

If you do not find the product listed here please call or E-mail and speak to the owner.

 


           


View the previous item
View the index page
View all items
View the next item

 

 


Superior Radiant Insulation - Type 6 (5 Layer) Multi Layer Aluminum Insulation

SUPERIOR TYPE 6 FLAME RETARDANT

THERMAL PERFORMANCE
DATA 2X6:

 

MATERIAL

R-VALUE
UP 

R-VALUE
DOWN      

MEAN
R-VALUE

SUPERIOR
TYPE 6

21.5

11.3

16

TYPE 6
W/CAP SHEET

24.9

13.3

19


Values shown are from ASTM C-236 guarded hot box test performed by a NVLAP accredited and State of California approved laboratory, and test data from ASHRAE fundamentals handbook. All R values for heat flow include 1.32 R for still air, and all R values for heat flow down includes 4.55 R still air.

MATERIAL
Superior type 6 flame retardant aluminum insulation is a five layer product, composed of four sheets of flame resistant Kraft paper, each faced on one side with aluminum foil and one sheet of aluminum foil without paper backing.

A higher insulation value and a more pleasing appearance will be achieved by adding Superior Factory Type 2 flame retardant cap sheet face stapled to the bottom of the rafters.

INSTALLATION
Grasp blanket by flange with printed side down, position blanket flush against perlin/plate at end of bay, leave gap " to 1" between bottom of flange and face of rafters/truss (when installed between 2"x4" roof rafters install " from of rafter), begin stapling material approx. 6" o.c. for full length of blanket. Hand held stapler is suggested with a minimum of 3/8" staple.

Grasp free flange and pull it taut towards the rafter/truss on right. Line bottom of flange up even with bottom of facing of rafter/truss. Be sure material is pulled evenly to prevent cross buckles and wrinkles. Finish by stapling full length approx. 6" o.c.

WARNING
Do not insulate under a wet roof deck. Insulating under a wet roof may cause condensation and damage to insulation
.

NOTE
All Superior Aluminum products incorporate the use of a special flame resistant paper manufactured to meet the National Bureau of Standards Voluntary Products Standard PS 46-71 for flame resistant paper. We use a water base non-flammable adhesive to bond the aluminum to the flame resistant paper.

When tested by the ASTM-84 flame spread test, all Superior products have achieved a flame spread of 25 or less.

Superior Aluminum Insulation products meet the State of California Quality Standards.



   Home    Materials    Occupied Applications    Roof Systems