Superior Radiant Insulation - Type 2 Silver Foil Capsheet

SUPERIOR FACTORY TYPE 2
ALUMINUM REFLECTIVE INSULATION

THERMAL PERFORMANCE
DATA 2 X 6:

Resistance Factor for Reflective Insulation Systems only

DOWN

R-12

UP

R-4.5

Installed Resistance Factor
Air to Air

DOWN

R-13

UP

R-5.9


Values shown are from ASTM C-236 guarded hot box test performed by a NVLAP accredited and State of California approved laboratory, and test data from ASHRAE fundamentals handbook. All R values for heat flow include 1.32 R for still air, and all R values for heat flow down includes 4.55 R still air.

MATERIAL
Superior Factory Type 2 aluminum reflective insulation is composed of 100LB. Kraft paper faced on both sides with aluminum foil. During the lamination process a heavy application of flame retardant adhesive is applied to both sides of the Kraft paper to make it flame resistant and achieve a low flame spread.

Superior Factory Type 2 is available with white on exposed facing.
Superior Factory Type 2 aluminum reflective insulation also has the following advantages:

  • Low in cost
  • Covers all roof rafters to give a simi-finished ceiling that never needs paint.
  • Increases light reflectivity, thereby decreasing the amount of light needed.
  • Is especially beneficial in an exposed rafter application in industrial and commercial
    buildings. When installed exposed below unfaced mineral fiber blanket insulation
    or multiple layer aluminum insulation , additional insulation value is achieved
    (see ASHREA guide for reflective insulation values). When tested for vapor trans-
    mission as per ASTM E 96 procedure B, the following results were achieved:
    WVT=).22 gm/M2.24 hr. performance = 0.22 perms, which meets CEC and
    UBC regulations.

RECOMMENDED METHOD OF SPECIFYING
Superior Factory Type2 aluminum insulation shall be installed only by qualified mechanics.

INSTALLATION
Face staple Superior Factory Type 2 to bottom of rafters, staples to be approximately 6" o.c. Material shall be installed as a single sheet the full length of the rafters and turned down approximately 1" at ends where possible, and stapled to both the perlin or main rafter support. Ends shall be neatly trimmed.

WARNING
Do not install insulation under a roof that is not dry. Insulating a wet roof may cause condensation and damage to insulation and roof deck.

NOTE
When tested by the ASTM E 84 Flame Spread Test the following results were achieved:
                         Flame Spread  5           Smoke Developed 15

Superior Aluminum Insulation products are state certified and meet the State of California Quality Standards.


Steel Truss Panelized Roof System

Bow String System Truss Roof

Wood Joist, Steel 1 Beam Roof System

Panelized Roof System
(Occupied Application)

 

 


Superior Radiant Insulation - Type 2 Black Foil Capsheet

SUPERIOR FACTORY TYPE 2
DECORATIVE BLACK  INSULATION

 


Superior Factory Type 2 is available with white or custom colors on exposed facing.
Superior Factory Type 2 black insulation also has the following advantages:

  • Low in cost
  • Covers all roof rafters to give a simi-finished ceiling that never needs paint.
  • Is especially beneficial in an exposed rafter application in industrial and commercial
    buildings. When installed exposed, below unfaced mineral fiber blanket insulation
    or multiple layer aluminum insulation , additional insulation value is achieved.

RECOMMENDED METHOD OF SPECIFYING
Superior Factory Type2  insulation shall be installed only by qualified mechanics.

INSTALLATION
Face staple Superior Factory Type 2 to bottom of rafters, staples to be approximately 6" o.c. Material shall be installed as a single sheet the full length of the rafters and turned down approximately 1" at ends where possible, and stapled to both the perlin or main rafter support. Ends shall be neatly trimmed.

WARNING
Do not install insulation under a roof that is not dry. Insulating a wet roof may cause condensation and damage to insulation and roof deck.

NOTE
When tested by the ASTM E 84 Flame Spread Test the following results were achieved:
                         Flame Spread  5           Smoke Developed 15

Superior Aluminum Insulation products are state certified and meet the State of California Quality Standards.

 

 


Superior Radiant Insulation - Type 2 White Foil Capsheet

SUPERIOR FACTORY TYPE 2
WHITE REFLECTIVE INSULATION

When a clean, bright finish is needed:
Increases light reflectivity 15% over aluminum

COMPLETED INSTALLATION PHOTOS

Image 01     Image 02     Image 03


Superior Factory Type 2 is available with white and custom colors on exposed facing.
Superior Factory Type 2 white insulation also has the following advantages:
  • Low in cost
  • Covers all roof rafters to give a simi-finished ceiling that never needs paint.
  • Increases light reflectivity 15% over aluminum, thereby decreasing the amount of light needed.
  • Is especially beneficial in an exposed rafter application in industrial and commercial buildings. When installed exposed below unfaced mineral fiber blanket insulation or multiple layer aluminum insulation , additional insulation value is achieved.

RECOMMENDED METHOD OF SPECIFYING
Superior Factory Type2 aluminum insulation shall be installed only by qualified mechanics.

INSTALLATION
Face staple Superior Factory Type 2 to bottom of rafters, staples to be approximately 6" o.c. Material shall be installed as a single sheet the full length of the rafters and turned down approximately 1" at ends where possible, and stapled to both the perlin or main rafter support. Ends shall be neatly trimmed.

WARNING
Do not install insulation under a roof that is not dry. Insulating a wet roof may cause condensation and damage to insulation and roof deck.

NOTE
When tested by the ASTM E 84 Flame Spread Test the following results were achieved:
                         Flame Spread  5           Smoke Developed 15

Superior Aluminum Insulation products are state certified and meet the State of California Quality Standards.

 

 


Superior Radiant Insulation - Type 2 Custom Color Foil Capsheet

SUPERIOR FACTORY TYPE 2
CUSTOM COLORS

Similar R-values as our other
capsheet products, only in designer
colors to match your decor.

Call for details

Photos of installed product


 

 


Superior Radiant Insulation - Type 4 (3 Layer) Multi Layer Aluminum Insulation

SUPERIOR TYPE 4
FLAME RETARDANT
ALUMINUM REFLECTIVE INSULATION

THERMAL PERFORMANCE
DATA 2"x 6":

 

MATERIAL

R-VALUE  
DOWN              UP

SUPERIOR TYPE 4

17.3

8.4

SUPERIOR TYPE 4
W/CAP SHEET

21.5

10.8


Values shown are from ASTM C-236 guarded hot box test performed by a NVLAP accredited and State of California approved laboratory, and test data from ASHRAE fundamentals handbook. All R values for heat flow include 1.32 R for still air, and all R values for heat flow down includes 4.55 R still air.

MATERIAL
Superior type 4 flame retardant aluminum insulation is a three layer product, composed or two sheets of flame resistant Kraft paper, each faced on one side with aluminum foil, and one of aluminum foil without paper backing.

A higher insulation value and a more pleasing appearance will be achieved by adding Superior Factory Type 2 flame retardant cap sheet face stapled to the bottom of the rafters.

INSTALLATION
Grasp blanket by flange with printed side down, position blanket flush against perlin/plate at end of bay, leave gap " to 1" between bottom of flange and face of rafter/truss (when installed between 2"x 4" roof rafters install from face of rafter), begin stapling material approx. 6" o.c. for full length of blanket. Hand held stapler is suggested with a minimum of
3/8" staple.
Grasp free flange and pull it taut towards the rafter/truss on right. Line bottom of flange up even with bottom of facing of rafter/truss. Be sure material is pulled over evenly to prevent cross buckles and wrinkles. Finish by stapling full length approx. 6" o.c.

WARNING
Do not insulate under a wet deck. Insulating under a wet roof may cause condensation and damage the insulation.

NOTE
All Superior Aluminum Insulation products incorporate the use or a special flame resistant paper manufactured to meet the National Bureau of Standards Voluntary Standard PS 46-71 for flame resistant paper.  We use a water base non-flammable adhesive to bond the aluminum to the flame resistant paper.
When tested by the ASTM E-84 flame spread test, all Superior products have achieved a flame spread of 25 or less.
Superior Aluminum Insulation products meet the State of California Quality Standards.

 

 


Superior Radiant Insulation - Type 5 (4 Layer) Multi Layer Aluminum Insulation

SUPERIOR FACTORY TYPE 5
ALUMINUM REFLECTIVE INSULATION

THERMAL PERFORMANCE
DATA  2"x 6":


MATERIAL

R-VALUE    

  DOWN                 UP

SUPERIOR
TYPE 5

20.3

10.2

TYPE 5
W/CAP SHEET

24.2

12.4


Values shown are from ASTM C-236 guarded hot box test performed by a NVLAP accredited and State of California approved laboratory, and test data from ASHRAE fundamentals handbook. All R values for heat flow include 1.32 R for still air, and all R values for heat flow down includes 4.55 R still air.

MATERIAL
Superior Type 5 flame retardant aluminum insulation is a four layer product, composed of three sheets of flame resistant Kraft paper, each faced on one side with aluminum foil, and one sheet of aluminum foil without paper backing.

A higher insulation value and a more pleasing appearance will be achieved by adding Superior Type 2 flame retardant cap sheet face stapled to the bottom of the rafters.

INSTALLATION
Grasp blanket by flange with printed side down, position blanket flush against perlin/plate at end of bay, leave gap " to 1" between bottom of flange and face of rafter/truss (when installed between 2"x 4" roof rafters install " from face of rafter), begin stapling material approx.
6"o.c. for full length of blanket. Hand held stapler is suggested with a minimum of 3/8" staple.

Grasp free flange and pull it taut towards the rafter/truss on right. Line bottom of flange up even with bottom of facing of rafter/truss. Be sure material is pulled over evenly to prevent cross buckles and wrinkles. Finish by stapling full length approx. 6" o.c.

WARNING
Do not insulate under a wet roof deck. Insulating a wet roof may cause condensation and damage to insulation.

NOTE
All Superior Aluminum Insulation products incorporate the use of a special flame resistant paper manufactured to meet the National Bureau of Standards Voluntary Product Standard
PS 46-71 for flame resistant paper. We use a water base non-flammable adhesive to bond the aluminum to the flame resistant paper.

When tested by the  ASTM-84 flame spread test, all Superior products have achieved a flame spread of 25 or less.

Superior Aluminum Insulation products meet the State of California Quality Standards.

 

 


Superior Radiant Insulation - Type 6 (5 Layer) Multi Layer Aluminum Insulation

SUPERIOR TYPE 6 FLAME RETARDANT

THERMAL PERFORMANCE
DATA 2X6:

 

MATERIAL

R-VALUE
UP 

R-VALUE
DOWN      

MEAN
R-VALUE

SUPERIOR
TYPE 6

21.5

11.3

16

TYPE 6
W/CAP SHEET

24.9

13.3

19


Values shown are from ASTM C-236 guarded hot box test performed by a NVLAP accredited and State of California approved laboratory, and test data from ASHRAE fundamentals handbook. All R values for heat flow include 1.32 R for still air, and all R values for heat flow down includes 4.55 R still air.

MATERIAL
Superior type 6 flame retardant aluminum insulation is a five layer product, composed of four sheets of flame resistant Kraft paper, each faced on one side with aluminum foil and one sheet of aluminum foil without paper backing.

A higher insulation value and a more pleasing appearance will be achieved by adding Superior Factory Type 2 flame retardant cap sheet face stapled to the bottom of the rafters.

INSTALLATION
Grasp blanket by flange with printed side down, position blanket flush against perlin/plate at end of bay, leave gap " to 1" between bottom of flange and face of rafters/truss (when installed between 2"x4" roof rafters install " from of rafter), begin stapling material approx. 6" o.c. for full length of blanket. Hand held stapler is suggested with a minimum of 3/8" staple.

Grasp free flange and pull it taut towards the rafter/truss on right. Line bottom of flange up even with bottom of facing of rafter/truss. Be sure material is pulled evenly to prevent cross buckles and wrinkles. Finish by stapling full length approx. 6" o.c.

WARNING
Do not insulate under a wet roof deck. Insulating under a wet roof may cause condensation and damage to insulation
.

NOTE
All Superior Aluminum products incorporate the use of a special flame resistant paper manufactured to meet the National Bureau of Standards Voluntary Products Standard PS 46-71 for flame resistant paper. We use a water base non-flammable adhesive to bond the aluminum to the flame resistant paper.

When tested by the ASTM-84 flame spread test, all Superior products have achieved a flame spread of 25 or less.

Superior Aluminum Insulation products meet the State of California Quality Standards.

 

 


Superior Radiant Insulation - Type 2 Scrim

Superior FSKF-10
Insulation Facing & Vapor Barrier

MATERIAL
Composition-.000285 Aluminum Foil both sides of 30 lb. Kraft (10 lbs. per thousand sq.ft.) with scrim reinforcing, laminated with a flame retardant adhesive.
  • Flame Spread 0 per ASTM E-84 Tunnel Test
  • Smoke Development- 0  per ASTM E-84 Tunnel Test
  • Perm-.02
  • Emisivity-.02
  • Insulating Value= R-12 Down R-4.5 up when installed as an individual application on the underside of a roof
    per ASTM C-236

INSTALLATION FOR ROOF DECKS
Install as a single unit spanning the entire length of the underside of the rafter, stapling approximately 6" o.c. and turning ends
down approximately 1" on supporting beams when possible.

OTHER USES
Superior FSKF-10 may be used anywhere a tough flame resistant vapor

barrier is required.

Lighting-Use of Superior FSKF-10 material on the underside of exposed
roof structure may increase lighting by up to 30%

Warning
Do not install this product under a wet roof deck as doing so may cause damage to both
the material and the deck.

NOTE
All Superior Aluminum Insulation Products are state certified and meet the State of California
Quality Standards.

 

 


Lamtec - WMP-10 Black

WMP-10 BLACK
Polypropylene / Scrim /Kraft


Click To Enlarge

 

Installed Products Image:

Small Restaurant

 

  MEETS ASTM C-1136, TYPE II,IV

FACING COMPOSITION

DESCRIPTION

VALUES

Coating Black .
Film Metallized White Polypropylene

.0015 in (+/- 10%)

Adhesive Flame Resistant .
Reinforcing Tri-directional

MD: 4 / inch

. Fiberglass/Polyester

XD: 4 / inch

Kraft White

14.0 lbs./3000 sf (+/- 10%)

 

FIRE TESTING               RESULTS                       FLAME SPREAD                 SMOKE DEVELOPMENT
UL-723/ASTM E-84         Film Exposed                               10                                         10
                                          Kraft Exposed                              15                                           5
 

 


Lamtec - WMP-10 White

WMP-10 WHITE
POLYPROPOLENE /SCRIM / KRAFT


Click To Enlarge

 

FACING COMPOSITION DESCRIPTION VALUES (ENGLISH) VALUES (METRIC)
White Film

Metallized Polypropylene

0.0015 inch

38.1 micron

Adhesive

Flame Resistant

. .
Reinforcing

Tri-directional

5 / inch (MD)

20 / 100mm (MD)

.

Fiberglass/Polyester

5 / inch (XD)

20 / 100mm (XD)

Kraft

White

14 lbs / 3000 ft

23 gm / m

 

FIRE TESTING               RESULTS                       FLAME SPREAD              SMOKE DEVELOPMENT
UL-723/ASTM E-84         Film Exposed                               10                                   10
                                           Kraft Exposed                              15                                      5
 

 


Lamtec - FSF Moisture Resistant

FOIL / SCRIM / FOIL
  MOISTURE RESISTANT


Click To Enlarge

 

FACING COMPOSITION

DESCRIPTION

VALUES  (ENGLISH)

VALUES (METRIC)

FOIL

Aluminum

0.0003 inch

7.6 micron

ADHESIVE

Flame Resistant

.

.

REINFORCING

Bi-directional

4/inch  (MD)

16/100mm (MD)

.

Fiberglass

4/inch  (XD)

16/100mm (XD)

FOIL

Aluminum

0.0003 inch

7.6 micron

 

FIRE TESTING               RESULTS                       FLAME SPREAD         SMOKE DEVELOPMENT
UL-723/ASTM E-84         Film Exposed                              10                           10
                                           Kraft Exposed                              15                             5